Replace a server with an assigned server profile
Server Hardware failure
Server hardware failed and must be replaced.
- Gracefully shut down the server hardware.
- Remove the original server and install the replacement server.
-
If the server hardware type of the replacement server matches the server hardware type of the original server, then:
If the Affinity defined in the profile is set to Device bay, the server profile will be automatically reassigned to the new server. Proceed to step 5.
If the Affinity is set to Device bay + server hardware, edit and save the server profile to allow the appliance to reconfigure the profile for the new server. No changes to the server profile are required. Proceed to step 5.
- If the server hardware type of the replacement server does not match the server hardware type of the original server, create a profile that matches the server hardware type of the replacement server. The original profile assigned to the server must be unassigned or deleted and the new profile assigned to the replacement server. Or, the server hardware type must be updated to match the inserted hardware.
-
If the
iLO firmware version is greater than or equal to the minimum required firmware version, proceed to Step 6. The minimum
iLO firmware version is available in the
HPE OneView Support
Matrix. If the replacement server has an
iLO firmware version less than the minimum required firmware version, an alert on the
Server Hardware screen is displayed and the server status is
Unmanaged/Unsupported Firmware.
Select Actions > Update iLO firmware.
Click OK.
-
If the
iLO firmware version is different from the baseline and the server profile is assigned to
a Gen8 server or later, the
iLO server firmware can be updated automatically with the reassignment of the server profile.
From the main menu, select SERVERS > Server Profiles, and then select the server profile to edit.
Select Actions > Edit. If needed, select the proper server hardware.
To manage the firmware update manually, from the Firmware baseline list, select managed manually.
To automatically update the firmware, select the appropriate firmware baseline. To install the firmware, select Force installation.
Click OK.
If the firmware version is different from the baseline and the server profile is assigned to a G7 server, update the firmware outside of the appliance.