Compute module environmental specifications

Specification Value
Temperature range*
Operating 10°C to 35°C (50°F to 95°F)
Non-operating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)**
Operating 8% to 90% @ -12°C - 24°C (10.4°F - 75.2°F)
Non-operating 5% to 95% relative humidity (Rh) @ 38.7°C (101.7°F), maximum wet bulb temperature, non-condensing
Altitude†
Operating 3050 m (10,000 ft)
Non-operating 9144 m (30,000 ft)

* The following temperature conditions and limitations apply:

  • All temperature ratings shown are for sea level.

  • An altitude derating of 1°C per 305m (1.8°F per 1,000.7 ft) above sea level

  • No direct sunlight is allowed.

  • The maximum permissible rate of change is 10°C/hr (18°F/hr).

  • The type and number of options installed might reduce the upper temperature and humidity limits.

  • Operating with a fan fault or above 30°C (86°F) might reduce system performance.

** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F).

† Maximum storage altitude corresponds to a minimum pressure of 70 kPa (10.1 psia).