Environmental specifications-system components support matrix
Environmental specification | Support status | ||||||
---|---|---|---|---|---|---|---|
Base system | Fans | SATA M.2 drives | NVME M.2 drives | PCIe cards | PXIe modules | ||
Standard Operating Support | Yes | Yes (with redundancy) | Yes | Yes | Yes | Yes (up to 38 W)1 | |
Extended Ambient 40°C Operating Support (ASHRAE Class A3 Compliant) | Yes | Yes (with redundancy) | Yes | Yes | Yes | Yes (up to 38 W)1 | |
Extended Ambient 45°C Operating Support (ASHRAE Class A4 Compliant) | Yes | Yes (with redundancy)2 | Yes | Yes3 | Yes | No | |
Extended Edgeline 0°C to 55°C Operating Support | Yes4 | Yes (with redundancy)2 | Yes | No | Yes5 | No |
1
Maximum altitude is 2,000 m (800 mbar) (at 25 °C ambient temperature)
2
Upon fan failure, the servers in the system might have reduced performance
3
M.2 drive might exceed its spec by 2°C to 3°C and have slight throttling.
4
Near 55°C inlet ambient temperature, when the CPU is stressed at 100%, the HPE m510 -16c server might have reduced performance.
5
The PCI card must have inlet spec rated at 65°C or higher, and an air speed of 375 ft/min.