Installing an LFF non-hot-plug drive in the drive cage

Prerequisites

Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.

Procedure
  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Disconnect all peripheral cables from the server.
  4. Do one of the following:
  5. Remove the front bezel.
  6. Remove the access panel.
  7. If installed, remove the air baffle.
  8. If there are drives already installed in the non-hot-plug drive cage, disconnect all cables from the drives.
  9. Remove the non-hot-plug drive cage:
    1. Remove the screws from the drive cage.
    2. Remove the non-hot-plug drive cage.

    Removing the non-hot-plug drive cage
  10. Install the drive.

    Installing the drive
  11. Install the non-hot-plug drive cage.

    Installing the non-hot-plug drive cage
  12. Connect the drive cables.
  13. If removed, install the air baffle.
  14. Install the access panel.
  15. Install the front bezel.
  16. Do one of the following:
  17. Connect all peripheral cables to the server.
  18. Connect the power cords:
    1. Connect each power cord to the server.
    2. Connect each power cord to the power source.
  19. Power up the server.

The installation is complete.

To configure arrays, see the HPE Smart Array SR Gen10 Configuration Guide at the Hewlett Packard Enterprise website.