NTP synchronization fails in HPE OneView
Appliance time and date settings do not match the NTP server.
Solution 1Cause Action
Appliance is not properly configured for NTP. The configuration of the appliance contains an error.
- As an Infrastructure administrator, verify that the host name or IP address you specified is an NTP server.
- Examine the Appliance panel of the Settings screen to confirm that the IP address of the NTP server is correct.
- Verify that the NTP server is not behind a firewall.
- If it is, you might need to modify the firewall settings.
- Verify that the NTP server is up and communicating.
- Synchronize the appliance clock with the NTP server. For more information, see the HPE OneView Help.
- Follow the procedure to synchronize the appliance clock with NTP server.
- Allow sufficient time for the appliance and the NTP server to synchronize. This could be as long as one hour for a global NTP server.
Solution 2Cause Action
Appliance time differs from NTP server by more than 1000 seconds. The appliance cannot synchronize with the NTP server.